EE 420L Engineering Electronics II Lab – Lab 5

Op-amps III, the op-amp integrator.

 

Authored by Shadden Abdalla

Email: abdals1@unlv.nevada.edu

March 13, 2019

 

PRELAB WORK:

Watch the video op_amps III, review notes and simulate circuits.

 

LAB WORK:

 

This lab uses the LM324 op-amp and assumes that VCC+ is 5V and VCC- is 0V.

 

Calculate the frequency response of the following circuit.

 

The calculations above show that the frequency is about 160Hz and the phase shift should be 90 degrees.

 

a.  What can you neglect to simplify the calculation?

You can neglect the Rbig resistor, 100k. It will only slightly change the output. In the calculation, it will only slightly change the result because of the ratio of R2 to R1. The huge resistor is there as the feedback path for the DC current. Without the resistor, the circuit will rail.

b.  Does the circuit work if you remove the 100k? Why or why not?

It does not work in a non-ideal circuit because the offset will cause it to rail. The huge resistor is there as the feedback path for the DC current. Without the resistor, the circuit will rail.

c.   Does the 100k have much of an effect on the frequency response?

It does not affect the frequency response significantly at all because the AC current affects the capacitor a lot more than it affects the resistor.

PART ONE

Show, at the unity-gain frequency of the integrator, that the input and the output have the same peak values.

Below is the frequency generator input of 160Hz which is what we calculated above with a 100mVpp amplitude and an offset of 2.5VDC. To the right is a photo of the circuit pictured above on the breadboard.

 

 

Below are the results on the oscilloscope. The yellow signal is the input and it measured a delta of 204mV. To the right is the measurement of the blue signal, the output of the circuit, which measured a delta of 148mV.

This shows that the circuit worked properly because were were trying to find the unity gain value. In order to do that, you divide the input delta by the square root of two to get the value of the output.

 

 

 

 

 

We changed the frequency until we got a value that is similar to the one we calculated, 144.25mV. We reached 140mV at a frequency of 220Hz.

 

Is the phase shift between the input and the output what you expect? Why or why not?

The phase shift is what we expect, there is a 90 degree phase shift between the two signals. You can see from the calculation above that the experimental reading matches the calculation. You can see the difference in the oscilloscope reading above. The output leads the input by 90 degrees.

PART TWO:

  We picked a capacitor in the lab which measured to be 0.427nF. From that value, we calculated the resistor value that we needed, which was about 100k. We calculated the resistor value based on the capacitor value to ensure the best results and measured the capacitor to create a more accurate oscilloscope reading. The tradeoff of using a smaller capacitor is that we need a larger resistor value, but we had both of those values, so it was not a huge problem.

The calculations above show how we choose to build the circuit. We found the period by using the frequency and solved for the resistor value by using the measured capacitor value. Below is the input signal from the frequency generator, with the circuit next to it on the breadboard. The output shows that the input, a square wave, produced a triangle wave. It was a slightly uneven circuit, but it is a triangle.

  

Conclusion and tradeoffs:

The LTSpice simulation confirms that our values work. It is centered about 2.5V and goes in between 1V to 4V. The LTSpice simulation is not exactly what we want because it is simulating the ideal case that I produced using the breadboard. That is why the values do not go exactly to 4V or 2.5V but they are very close because it is a non-ideal case. The tradeoffs regarding the average values leveled out and overall, the output was what we intended it to be. For my input peak, I used a square wave that went from 0 to 5 in order to make it easier to get from 1 to 4. I also choose those values in order to get closer to VCM and have an average that is very close to VCM to reduce offset.

 

 